Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
91
4
4.4
Configuration
4.4.1
Power unit
All the power unit related data are divided into two groups. The first group includes the
so-named power unit data which is shown in parameter group
129
and cannot be written
to.
The power unit has a non-volatile memory which holds the power unit data. When the
controller is initialized, these data are read out and transferred to the corresponding pa-
rameters in group
129
.
The second group, parameter group
130
, contains all the other power unit working data.
These parameters represent either constantly changing physical quantities or certain set-
tings which generally can be altered.
Detection of a mains failure
The detection of mains failure at external supply is possibly not fast enough for specific
applications. Therefore a mains failure detection is optionally possible via the DC link volt-
age (see
).
Behavior at mains failure
The drive can be configured that operation is possible at a mains failure for a set time
(
). Different kinds of behavior can be set (see
– Disable only motor operation (generator operation is enabled, field current is further
supplied). This behavior is only possible at external supply.
– Normal operation (motor and generator operation): Normally this option makes only
sense at a DC link combination if another axis feeds back power to the DC link. This
behavior is only possible at external supply.
– Disabling and automatic restart: The pulses are inhibited in case of detected mains
failure. The drive changes to "Switch-on inhibit (1)" state and coasts down. If the time
of the mains failure is shorter than the set Mains failure delay (
), the drive
restarts automatically. The drive changes automatically in the "Operation enabled"
state again.