Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
110
4.4
If the current limit safety function of the overload monitoring PU temperature model has
responded, the maximum current of the drive
is limited to the max. PU instanta-
neous value of continuous current
>
175.7
<
. See
Overload monitoring of the power
175.8
PU I2t max. continuous current actual value
From controller version V01.09 onwards.
The parameter displays the instantaneous value of the maximum accepted continuous
current of the conductors and capacitors.
Important for devices, which support the PU temperature model (see status PU tempera-
ture model
The parameter is generated from the nominal current 2 kHz (
), whereat the fol-
lowing correction factors are considered, which are described in "Operating conditions"
of the operating manual of the device.
m
Correction factor of the device's control cabinet temperature (ambient temperature
or surface temperature). The required temperature can be entered in parameter
m
Correction factor of installation altitude. The required installation altitude can be en-
tered in parameter
.
The parameter displays the scaling factor of the I
2
t-sub-model (part of the PU tempera-
ture model).See