4.7
18.61
Position error angle
Display of the position error in 32-bit integer format.
The resolution is 32 bits per revolution.
18.62
Position error revolutions
Display of the position error in revolutions in 32 bit integer format.
A 0 or -1 signifies no position error in the revolution.
18.68
Speed additional value
Additional speed set value.
Units: degrees/s
18.69
Speed set value
Display of the speed set value from the set value manager in degrees/s.
With speed control (
= 13):
With absolute position control (
= 12):
w2 Speed set value =
Speed set value *
w2-feedforward Factor
+
Speed additional value
+
e1 Position Controller Error *
18.70
w2-Feedforward time constant
Time constant of the speed feedforward.
The speed feedforward is implemented as DT1 element. All changes to the position set
value are differentiated with respect to time, smoothed with the
>
18.70
<
feedforward time
constant and multiplied subsequently by the parameter
w2-Feedforward factor.
Due to minimize the position error e1, it is recommended that the w2-Feedforward time
constant is set to Time constant speed act. value filter
For synchronous operation on actual master axis (= encoder) the parameter for smooth-
ing the master axis set value (w2-feedforward part) can be used.