1506
HPI buffer is full
HPI buffer has user data available or old telegram data are not
called for yet.
No response
1507
TCP IP Stack could not be initialized
An error has occurred at initialization of TCP/IP stack
No response
1508
SoE firmware error message
SoE firmware (Servodrive-Profile over EtherCAT) sends an error
message to the drive controller. The error reaction is started by the
SoE firmware of the fieldbus processor.
No response
1509
EtherCAT IP core cannot init EEPROM
No response
1510
Sub device index invalid
Sub device index invalid, i.e. out of range
No response
1511
Firmware error fieldbus controller
Fieldbus controller signaled a firmware error.
No response
1512
Faulty backup of operation data
No response
1513
Illegal drive address
A invalid drive address is set.
No response
1514
Error caused by memory allocation
No response
1515
Faulty task start
Operating system was not able to start a task.
No response
1516
Faulty init of scaling data
No response
1517
Error during reading of the cyclic actual
values
No response
1518
Error during writing of the cyclic set val-
ues
No response
1519
Critical GDP error while initialization
Incorrect reading or writing of important data via GPD. GPD means
the communication between controller and fieldbus controller.
No response
1520
Invalid version of the controller firm-
ware
Installed controller firmware cannot be used with this type of field-
bus. Version see controller parameter P102.2 or IDN P-0-0221
No response
1521
Warning: Error while reading service
data
No response
1522
Warning: Error while writing service
data
No response
1523
Error during command execution
An error occurred during a command execution.
No response
1524
Timeout during command execution
A timeout occurred during a command execution.
No response
1525
MST-Error; drive controller lost syn-
chronization
Sercos: MST incorrect
SoE: controller signaled lost synchronization
No response
1526
Error: MDT miss twice; watchdog time-
out process data
Sercos: failure of MDT (MDT miss twice)
SoE: watchdog timeout at process data
No response
1527
Error during switch up of phase
Error during switch up of the bus state
(phase switch up)
No response
1528
Error during switch down of phase
Error during switch down of the bus state
(phase switch down)
No response
1529
Phase transition without ready
acknowledge
Sercos:
n
switch up to CP3 not possible
back to CP0.
n
switch up to CP4 not possible
back to CP0.
SoE:
n
switch up to Safe-Op not possible
back to Pre-OP.
n
switch up to Op not possible
back to Safe-OP.
No response
1530
Error: Invalid phase
Invalid phase (bus state) set.
No response
1531
Switch to non-initialized operation
mode
Switch to a not supported or unknown operation mode.
No response
1532
Error: Two drives with same address in
ring
Error message only possible using Sercos.
No response
Error
num-
ber
Brief error text
Error description
Default set-
ting for
Error
Response
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......