![Baumuller b maXX BM2500 Скачать руководство пользователя страница 298](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400298.webp)
Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
298
4.4
4.4.20 Synchronization
4.4.20.1 Parameter overview
Functional block:
FbSynchronisation[156]
4.4.20.2 Description of the Parameters
156.1
Mode
Switch on or switch off synchronization to fieldbus signal.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Su
pp
ort
C
yclic W
rite
156.1
Mode
UINT
0
1
0
1:1
X
156.2
Status
UINT
0
0xFFFF
0
1:1
X
156.3
Sync tolerance
UINT
0
0x1FFF
1000
µs
1000:20
X
156.4
Sync offset
DINT
-2147483648
2147483647
0
µs
1000:20
X
156.5
Fieldbus cycle
UDINT
0
4294967295
0
µs
1000:20 X
156.6
Fieldbus jitter
DINT
-2147483648
2147483647
0
µs
1000:20 X
156.7
Sync error
DINT
-2147483648
2147483647
0
µs
1000:20 X
156.8
Max. jitter positive
DINT
0
262144
0
µs
1000:20
156.9
Max. jitter negative
DINT
-262144
0
0
µs
1000:20
156.15
Time fieldbus write access
DINT
-500000
500000
0
µs
1000:20 X
156.16
Time DSP read access
DINT
-500000
500000
0
µs
1000:20 X
156.17
Time DSP write access
DINT
-500000
500000
0
µs
1000:20 X
156.18
Time fieldbus read access
DINT
-500000
500000
0
µs
1000:20 X
156.19
Time fieldbus read to DSP
read
DINT
-500000
500000
0
µs
1000:20 X
Bit
Meaning
0
0: Synchronization is switched off
1: Synchronization is switched on
1
0: Automatic adjustment of the Sync offset
Содержание b maXX BM2500
Страница 740: ...Monitoring Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 740 of 820 4 11 ...
Страница 814: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 814 of 820 ...
Страница 820: ...Parameter manual b maXX BM3000 Document no 5 12001 07 Baumüller Nürnberg GmbH 820 of 820 Notizen ...
Страница 821: ......