The cause of error will be displayed in this parameter.
Not generally all error messages were supported (see
Alarm mask).
The controller responds to a set error bit with a corresponding error (error numbers 406
to 412).
137.38
Warning mask
The parameter is only valid for EnDat
®
encoders.
The supported warnings of the connected encoder type are shown.
137.39
Warning buffer
The parameter is only valid for EnDat
®
encoders.
The warnings of the connected encoder type are displayed in this parameter. The ex-
ceeded requirements of tolerance for specific encoder internal values are displayed.
It is not assumed that position value are wrong at warnings contrary to error messages.
Bit
Monitoring according to
0
1: Illumination failure
1
1: Signal amplitude faulty
2
1: Position value faulty
3
1: Overvoltage occurred
4
1: Undervoltage supply
5
1: Overcurrent occurred
6
1: Battery change needed
Residual
Reserved
Bit
Supported warnings
0
1: Collision of frequency
1
1: Excess temperature
2
1: Lighting controller reserve
3
1: Battery load
4
1: Reference point crossed
Residual
Reserved