KANE455 

Quick Reference Guide 

 

 

 

 

 

 

 

 

       Infra-red emitter and torch light 

 
 
 
 
 
 

 

 

 

 

 

 

 

             

 

 

 

 

 

 

 

 

 

 

 

 

     Menu controls ~ Scroll up/down 

 

 

 

 

 

 

 

 

 

 

 

  

Enter 

Function buttons x 4 
    (See below for details) 
 
               Rotary switch   
 

 

 

 

 

 

 

 

 

 

 

      Particle filter 

 

 

 

 

 

 

 

 

 

 

 

Water trap 

“Battery charging” indicator                  
 
 

 

 

 

 

 

                        

 

 

Analyser Connections 

 

 

 

 

 

 

 

  Flue Gas Inlet 

(see diagram overleaf) 

 

 

 

 

 

 

        (see diagram overleaf) 

 

 

ON / OFF 

Turns the analyser ON / OFF

 

 

BACKLIGHT 

Switches backlight & torch light 
ON / OFF 

 

PUMP 

Turns the pump ON / OFF 
Hold button to zero pressure

 

 

SEND / ENTER 

Send readings to printer 
(Press button for 1 second.) 
Send readings to memory 
(Hold button down for 2+ secs.)

 

 

Stock No. 18839-2     July 2014 

 
© Kane International Ltd  

Содержание 455

Страница 1: ...rging indicator Analyser Connections Flue Gas Inlet see diagram overleaf see diagram overleaf ON OFF Turns the analyser ON OFF BACKLIGHT Switches backlight torch light ON OFF PUMP Turns the pump ON OF...

Страница 2: ...connection Flue Gas Inlet Watertrap Drain with Red Screw Plug Flue probe temperature T1 Inlet temperature T2 Pressure connection P1 Pressure connection P2 differential Fit Spigot to Hose before connec...

Страница 3: ...Current date Can be set via the Menu see section 11 Number of days until next check and calibration is required Note Boiler inlet air temperature can either be a Set automatically by the flue probe d...

Страница 4: ...e pressure sensor Using the black connectors and manometer hose connect to P1 for single pressure or P1 and P2 for differential pressure PRS display PRESSURE P 0 04 mbar 12 56 29 Defaults to smoothing...

Страница 5: ...be printed immediately or later from the memory Note The analyser s memory can store up to 20 tightness tests Tightness tests are logged automatically therefore the tightness section of the memory wil...

Страница 6: ...HER DISPLAY CODES PO Pump Off OC Open Circuit on temperature input 9 FOR BEST PRESSURE SENSOR ACCURACY 1 Switch the analyser on for 5 minutes to let the temperature stabilise 2 Zero the pressure senso...

Страница 7: ...minute TIGHTN S Set duration of tightness test in minutes Default 2 minute REPORT COMB N Stored combustion tests VIEW DEL ALL or EXIT max 99 tests PRESSURE Stored pressure tests VIEW DEL ALL or EXIT...

Страница 8: ...o C 17 2 Appliance Customer NETT o C 37 9 Ref Appliance EFF C 98 3 LOSSES 1 7 Ref XAIR 34 8 C a l d u e o n 0 1 0 7 1 5 KANE455 V 1 00B YOUR COMPANY NAME PHONE NUMBER HERE SERIAL NO 000000000 CO CO2...

Страница 9: ...tle Company Name Company Address 1 Address 2 Town City County Postcode Country Phone Number Fax Number Mobile Number Email Address Product Details Note Proof of Purchase may be required for warranty c...

Страница 10: ...ecommendation Internet Search Exhibition Other Which do you read most often Often Sometimes Hardly Ever Registered Gas Engineer Gas Installer P H P I P H A M News Heating Ventilating Plumbing Heating...

Страница 11: ......

Страница 12: ...ying this analyser Before use please register on our website www kane co uk Scan the QR code to go directly to Register your Product on line or complete detach and return the Product Registration form...

Отзывы: