124
4.2.2 Connection
4.2.2.1 Connecting to the CMU or the EMU
HCS-8385 interpreter unit is equipped with a 6P-DIN
cable with a standard male connector. When connecting
to the CMU or the EMU, just connect the male connector
of the first unit to the output of the main unit.
If there is a long distance between the congress unit and
the CMU (EMU), CBL6PS extension cable can be used.
One end is equipped with a 6P-DIN male connector and
the opposite end with a female connector. Just connect
the female connector of the cable to the next congress
unit, and connect the male connector to the output of the
main unit.
Figure 4.2.2 HCS-8385 Interpreter unit connected to the
CMU or the EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units if
“daisy-chain closed-loop” connection topology is
selected. Ring connection, achieved by closing the loop
of the daisy-chained units, increases system reliability.
To obtain “daisy-chain” ring connection just connect the
last congress unit back to the CMU with a CBL6PP
extension cable (the cable features a 6P-DIN male
connector at each end). In HCS-8300 Paperless
Multimedia Congress System, only the congress main
unit can realize a “Closed Loop - Daisy Chain”
connection, the extension main unit does not have this
feature.
Figure 4.2.3 Ring connection between the CMU and
HCS-8385 Interpreter units
4.2.2.2 Connection between Interpreter units
All HCS-8385 units are daisy-chained easily and
conveniently by dedicated 6-pin cables.
When connecting to another unit, just connect the
6P-DIN standard female connector on the cable of the
unit to the 6P-DIN standard male connector on the cable
of the next unit.
Figure 4.2.4 “Daisy-chain” connection between HCS-8385
Interpreter units
4.2.2.3 External earphone
An external headphone can be connected to the TRRS
jack at the lateral side of the Interpreter unit. Its volume
can be adjusted by the earphone volume control knob.
The external headphone shall have a Ø 3.5 mm plug
according to the following figure:
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...