6.4.3 Configuration and operation
When installation and connection are finished, the
Booth
Combiner
HCS-8300MX/FS
should be
configured by the front panel menu operation or the
RoomBoothCombine software prior to the meeting.
The room combination and booth combination
functions are controlled by RoomBoothCombine
software.
A) Starting initialization
B) Initial interface on LCD
The LCD interface displays the room name and work
mode of the current Booth Combiner.
The first row shows the room number and the room
name;
The second row shows current work mode, the
HCS-8300MX/FS Booth Combiner has six work
modes:
Idle Mode:
no booth combination and no
room combination;
Master Mode:
the mode of master
conference room after room combination;
Slave Mode:
the mode of slave conference
room after room combination;
Tenant Mode:
the mode of conference
room which borrows booths in booth
combination;
Landlord Mode:
the mode of conference
room which lends booths in booth
combination;
Master Mode + Tenant Mode:
the mode of
master conference room which borrows
booths in room combination and booth
combination.
Note:
One HCS-8300MX/FS can lend its booths to
only one HCS-8300MX/FS, and not to several
HCS-8300MX/FS at the same time;
One HCS-8300MX/FS cannot borrow as well
as lend booths at the same time.
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...