57
3.2.2 Connection
3.2.2.1
Connecting to the CMU or the EMU
HCS-8315 series congress unit is equipped with a
1.5-meter long 6P-DIN cable with a standard male
connector. To connect to the HCS-8300 CMU or the
EMU, just connect the male connector of the first unit to
the output of the main unit.
If there is a great distance between the congress unit
and the CMU (EMU), CBL6PS extension cable can be
used. One end is equipped with a 6P-DIN male
connector and at the opposite end with a female
connector. Just connect the female connector of the
cable to the next congress unit, and connect the male
connector to the output of the main unit.
Figure 3.2.2 HCS-8315 series congress unit connected
to the CMU or the EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units
if “Closed Loop - Daisy Chain” connection topology is
selected. Ring connection, achieved by closing the
loop of the daisy-chained units, increases system
reliability. To obtain “daisy-chain” ring connection, just
connect the last congress unit back to the CMU with a
CBL6PP extension cable (the cable features a 6P-DIN
male connector at each end).
In HCS-8300 Paperless
Multimedia Congress System, only the congress main
unit can realize a “Closed Loop - Daisy Chain”
connection, the extension main unit does not have this
feature.
Figure 3.2.3 Ring connection between the CMU and
HCS-8315 series congress units
3.2.2.2
Connection between congress units
All congress units of HCS-8300
PMCS are
daisy-chained easily and conveniently by dedicated
6P-DIN cables.
When connecting to another congress unit, just
connect the 6P-DIN standard female connector on the
0.6-meter cable of the unit to the 6P-DIN standard male
connector on the1.5-meter cable of the next unit.
Figure 3.2.4 “Daisy-chain” connection between
HCS-8315 series congress units
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...