154
6.1.2 Connection
HCS-8300MO converts the digital audio signals of the
congress system to multi
channel
digital(AES/EBU)/analog audio signals, for further
processing in infrared simultaneous interpretation
systems or recording devices. The audio signal from the
HCS-8300M CMU can be provided to the HCS-5100
digital infrared language distribution system, converted
into an infrared signal and radiated. With digital infrared
receivers, the participators can hear the voice clearly.
The digital audio signal from the HCS-8300M CMU can
be connected directly to the DCS interface of the
HCS-5100MA(F)/N transmitter. But the HCS-5100MC/N
transmitter does not have the DCS interface and the
digital audio signal issued by the HCS-8300M CMU has
first to be converted into an analog signal via the
HCS-8300MO 8 Channels Audio Output Device and
secondly be provided to the HCS-5100MC/N transmitter.
1. HCS-8300MO
can be connected directly to
HCS-8300M CMU in three ways (only one of them can
be used at one time):
♦
Connect the "EXTENSION" interface of the
HCS-8300 CMU to the "EXTENSION IN" interface
of the HCS-8300MO with a Cat. 5 cable.
♦
Connect one outlet (6P-DIN) of the HCS-8300
CMU to the "DELEGATE IN" interface of the
HCS-8300MO with a dedicated 6-pin cable.
♦
Connect the fiber port of the HCS-8300MAU/FS or
HCS-8300MAD/FS/20 to the fiber port of the
HCS-8300MO/FS(D) transmitter.
2. 8 channels unbalanced audio can be outputted from
the 8x RCA outlets. HCS-5100MC/N has 4-channel
/8-channel /16-channel /32-channel (merge mode)
audio input ports (RCA). Connect the audio outputs of
the HCS-8300MO to the INPUT CH0-CH7 of the
HCS-5100MC/N with audio cable. HCS-8300MO can
be cascaded if more than 8 channels are needed.
3. The digital infrared transmitter is connected to the first
radiator by a 75 Ohm coaxial cable. Connect one BNC
plug of the coaxial cable to the “HF OUT” port of the
HCS-5100MC/N and the other BNC plug to the
“MODULATION IN” port of the 1
st
radiator. When
connecting to the 2
nd
radiator, connect the
“MODULATION OUT” port of the 1
st
radiator to the
“MODULATION IN” port of the 2
nd
radiator with a
coaxial cable. Up to 30 daisy-chained radiators can be
operated from each socket (6 sockets per transmitter).
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...