38
a). Press the “
/
” button to select “Yes” or “No”;
b). Press the “MENU” button to save and return to
upper level menu.
23. Video Tracking Setting
Enable/disable video tracking function.
a). Press the “
/
” button to select “Yes” or “No”;
If “No” is selected, press the “MENU” button to
confirm and return to upper level menu;
If “Yes” is selected, press the “MENU” button to
go to step b);
b). Press the “
/
” button to select “FIFO” or “VIP
first”;
“
FIFO
” is selected: when current video tracking
microphone is deactivated, video camera will
turn to last active microphone automatically;
“
VIP First
” is selected: when current video
tracking microphone is deactivated, video
camera will turn to the first activated chairman
unit or VIP unit;
“
VOX
” is selected: when working under OPEN /
OVERRIDE / VOICE mode, video camera will
turn to the speaking microphone automatically;
c). Press the “MENU” button to save and return to
upper level menu.
24. Select Master/Slave Mode
If two CMU are installed in one system, they are set as
“Master Mode” and “Slave Mode” separately.
a). Press the “
/
” button to select “Master” or
“Slave”:
If “Master Mode” is selected, press the “MENU”
button to confirm and return to upper level menu;
If “Slave Mode” is selected, press the “MENU”
button to confirm and go to step b);
b). Press the “
/
” button to select “Enable” or
“Disable”;
If “Enable” is selected, slave CMU will backup
master CMU automatically during the meeting
process. If master CMU stops, slave CMU will
switch automatically to master mode and act as
master CMU;
If “Disable” is selected, slave CMU will backup
master CMU automatically in the meeting
process. If master CMU stops, slave CMU will
NOT switch to master mode;
c). Press the “MENU” button to save and return to
upper level menu.
25. Infrared MU Setting
a). Press the “
/
” button to select “On” or “Off”;
If “Off” is selected, press the “MENU” to save
and return to upper level menu;
If “On” is selected, press the “MENU” button to
go to step b);
b). Setup infrared MU IP address, the same as
26. Sampling Rate Setting
Select sample rate between 32 kHz and 48 kHz. If “48
kHz” sampling frequency is selected, the system
response frequency is 30 Hz - 20k Hz; if “32 kHz”
sampling frequency is selected, the system response
frequency is 30 Hz - 16 kHz.
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...