112
4.1.3 Connection
4.1.3.1 Connecting to the CMU or the EMU
HCS-4385U/50 interpreter unit is equipped with a
6P-DIN cable with a standard male connector. When
connecting to the CMU or the EMU, just connect the
male connector of the first unit to the output of the main
unit.
If there is a long distance between the congress unit and
the CMU (EMU), CBL6PS extension cable can be used.
One end is equipped with a 6P-DIN male connector and
the opposite end with a female connector. Just connect
the female connector of the cable to the next congress
unit, and connect the male connector to the output of the
main unit.
Figure 4.1.3 HCS-4385U/50 Interpreter unit connected to
the CMU or the EMU
Neither the replacement of congress units nor cable
faults between congress units will affect the other units if
“daisy-chain closed-loop” connection topology is
selected. Ring connection, achieved by closing the loop
of the daisy-chained units, increases system reliability.
To obtain “daisy-chain” ring connection just connect the
last congress unit back to the CMU with a CBL6PP
extension cable (the cable features a 6P-DIN male
connector at each end). In HCS-8300 Paperless
Multimedia Congress System, only the congress main
unit can realize a “Closed Loop - Daisy Chain”
connection, the extension main unit does not have this
feature.
Figure 4.1.4 Ring connection between the CMU and
HCS-4385U/50 Interpreter units
4.1.3.2 Connection between Interpreter units
All HCS-4385U/50 units are daisy-chained easily and
conveniently by dedicated 6-pin cables.
When connecting to another unit, just connect the
6P-DIN standard female connector on the cable of the
unit to the 6P-DIN standard male connector on the cable
of the next unit.
Figure 4.1.5 “Daisy-chain” connection between
HCS-4385U/50 Interpreter units
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...