![Taiden hcs-8300 Installation And Operation Manual Download Page 53](http://html1.mh-extra.com/html/taiden/hcs-8300/hcs-8300_installation-and-operation-manual_813761053.webp)
40
a). Press the “
/
” button to select “Yes” or “No”;
If
“Yes”
is selected, force handheld microphone
to PTT mode;
If
“No”
is selected, handheld microphone works
the same as the stem microphone;
b). Press the “MENU” button to save and return to
upper level menu.
32. Extension Port Setting
Enable/disable extension port on the backside of the
CMU.
a). Press the “
/
” button to select “Yes” or “No”;
b). Press the “MENU” button to save and return to
upper level menu.
33. Fiber Port Setting
Enable/disable fiber port on the backside of the CMU.
a). Press the “
/
” button to select “Yes” or “No”;
b). Press the “MENU” button to save and return to
upper level menu.
34. CobraNet Bundle Setting
Setup Cobranet Tx and Rx bundle.
(HCS-8300MAU/FS)
a). Press the “
/
” button to select Tx bundle or Rx
bundle;
b). Press the “MENU” to confirm;
c). Press the “
/
” button to set port number (press
and hold the “
/
” button will adjust numeric value
quickly);
d). Press the “EXIT” to save and return to the upper
level menu.
34. CobraNet/Dante Output Setting
Enable/disable cobranet/dante output of the CMU.
(HCS-8300MAU/FS)
(HCS-8300MAD/FS/20)
a). Press the “
/
” button to select “Disable” or
“Enable”;
b). Press the “MENU” button to save and return to the
upper level menu.
35. Single Mic Output Mode
Set up single microphone output mode.
a). Press the “
/
” button to select “On” or “Off”,
When selected “On”, microphone 1~6 was
transmitted to group out 1~6 respectively. It is used
for microphone recording, and under this mode, the
mixer and group out volume adjusting are
unavailable;
b). Press the “MENU” button to save and return to the
upper level menu.
36. Conference Room Setting
This function is used for conference room combination
and interpreter booth sharing.
a). Press the “
/
” button to set conference room ID,
the maximum number is 1000;
b). Press the “MENU” button to set conference room
name, the maximum length is 16 characters;
Press the “MENU” button to enter the name
setting interface, the cursor blinks under the first
character;
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...