![Taiden hcs-8300 Installation And Operation Manual Download Page 31](http://html1.mh-extra.com/html/taiden/hcs-8300/hcs-8300_installation-and-operation-manual_813761031.webp)
18
Chapter 2 Congress main unit (CMU)
The congress main unit (CMU) forms the core of the
HCS-8300 Series Paperless Multimedia Congress
System, It provides power supply to contribution units
and serves as the key component to link up hardware
with application software. In stand-alone mode without
a PC, the CMU carries out basic management facilities;
Comprehensive
management facilities can be
implemented in PC-controlled mode.
The following devices can be controlled by the CMU:
discussion unit(chairman unit/delegate unit), voting unit,
Interpreter unit, video switch for automatic video
tracking, etc. By cascade connecting EMUs, HCS-8300
system can reach its maximum capacity: 378
simultaneous Interpreter units, 4096 discussion/voting
units and an infinite number of channel selectors.
The maximum system capacity is 378 Interpreter units,
4096 discussion/voting units and any number of
channel selectors.
Product types:
HCS-8300MAU/FS
Fully Digital Congress System Main Unit (discussion, voting, 64
CHs, 256x32 LCD, MIC. group outputs, AES/EBU digital
input/output, single-mode optical fiber interface, CobraNet
interface)
HCS-8300MAD/FS/20
Fully Digital Congress System Main Unit (discussion, voting, 64
CHs, 256x32 LCD, MIC. group outputs, AES/EBU digital
input/output, To Mixer interface, single-mode optical fiber
interface, Dante interface)
HCS-8300MB/20
Fully Digital Congress System Main Unit (discussion, voting, 64
CHs, 256x32 LCD, MIC. group outputs)
HCS-8300MB
Fully Digital Congress System Main Unit (discussion, voting, 64
CHs, 256x32 LCD, MIC. group outputs)
HCS-8300ME/FS
Fully Digital Congress System Extension Main Unit (with 2
single-mode optical fiber interfaces)
HCS-8300ME
Fully Digital Congress System Extension Main Unit
HCS-8300MES
Fully Digital Congress System Extension Unit
Summary of Contents for hcs-8300
Page 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Page 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Page 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Page 93: ...80 B About Display the product information including unit ID serial and version ...
Page 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Page 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Page 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Page 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Page 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Page 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Page 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Page 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...