Store in a way that protects the batteries
against short circuits
–
Store batteries at a safe distance from flam-
mable materials
–
Do not store batteries together with metallic
objects
–
Store lithium-ion batteries separately from
other types of batteries (no mixed storage)
–
Maintain a safety margin of at least 2.5 m
from other goods
–
To avoid a deep discharge, observe the
specifications of the battery manufacturer
regarding the maximum permissible storage
period
–
If you have any questions, contact your au-
thorised service centre.
Checking the battery charge sta-
tus
The charge state of the lithium-ion battery can
be read on the display-operating unit of the
industrial truck and on the display of the lithi-
um-ion battery.
Reading the display-operating unit
–
Apply the parking brake.
–
Switch on the key switch.
–
Read the charge state from the display.
–
Charge a discharged or partly discharged
battery.
Meaning of the colours in the display
1
Green:
The charge state is > 10%.
The battery is sufficiently charged
2
Yellow:
The charge state is ≤ 10%.
Charge the battery soon.
3
Red:
Stop working. Charge the battery imme-
diately. The battery is at risk of deep dis-
charge.
Operation
4
Handling the lithium-ion batteries
220
50078078001 EN - 07/2022 - 04
Summary of Contents for LXT 120
Page 2: ......
Page 12: ......
Page 13: ...1 Foreword ...
Page 37: ...2 Safety ...
Page 59: ...3 Overviews ...
Page 62: ...Overviews 3 Display control unit 50 50078078001 EN 07 2022 04 ...
Page 63: ...4 Operation ...
Page 265: ...5 Maintenance ...
Page 285: ...6 Technical data ...
Page 323: ......