The battery door must remain open during
charging.
–
Expose the surfaces of the battery cells.
–
Do not place any metal objects on the bat-
tery.
–
Fully open any protective structures (e.g.
fabric-covered cab).
–
Have fire extinguishing equipment ready.
Performing battery maintenance
The cell covers of the battery must be kept dry
and clean.
Terminals and cable shoes must be clean,
lightly coated with battery grease and screwed
on tightly.
–
Neutralise any spilt battery acid immediate-
ly.
–
Observe the safety regulations for handling
battery acid; see the chapter entitled "Bat-
tery acid".
Damage to cables and battery male
connectors
CAUTION
There is a risk of short circuit if cables
are damaged.
Do not crush the battery cable when
closing the battery door.
–
Check the battery cable for damage.
–
When removing and reinstalling the
battery, ensure that the battery cables
are not damaged.
–
Ensure that the battery cable does
not collide with the battery door.
Operation
4
Handling the lead-acid batteries
204