Deal with the fault according to the solution
described under "Description/possible solu-
tion".
–
Switch the industrial truck off and on again.
–
If the message still appears, please contact
the authorised service centre.
The messages are sorted in ascending order according to their code:
Code
Shown on display
Description/possible solution
A2305
Fault: Control unit
Collective fault on the control unit
A2899
Monitoring
Collective fault with process monitoring
A3027
Fault: Seat switch
The seat switch does not open
- Stand up from the driver's seat and sit down
again.
A3035
Fault: Brake fluid
Brake fluid switch
A3143
Check lift height sensor
and reflector
Lift-height sensor measurement error
A5934
Re-insert charging
plug
Error on the charging connector detection
- Disconnect the connection assembly and re-
connect it.
A5961
Battery overtempera-
ture
Overtemperature of the lithium battery
- Switch off the industrial truck and leave it to
cool down.
A5962
Battery too cold
Insufficient lithium battery temperature
- Move the industrial truck to a warmer environ-
ment.
A5986
Fault: Control unit
General battery current measurement
A5993
Fault: Internal charg-
er
On-board charger collective fault
A6502
Overtemp.: Parking
brake
Electric parking brake detects overtemperature
A6510
Fault: Parking brake
Electric parking brake detects fatal fault
A6511
Fault: Parking brake
Brake cannot release
A6512
Fault: Parking brake
Brake cannot apply
None
Error
General fault
Operation
4
Display messages
240
50078078001 EN - 07/2022 - 04
Summary of Contents for LXT 120
Page 2: ......
Page 12: ......
Page 13: ...1 Foreword ...
Page 37: ...2 Safety ...
Page 59: ...3 Overviews ...
Page 62: ...Overviews 3 Display control unit 50 50078078001 EN 07 2022 04 ...
Page 63: ...4 Operation ...
Page 265: ...5 Maintenance ...
Page 285: ...6 Technical data ...
Page 323: ......