CAUTION
Risk of component damage!
If the plug for the battery charger is disconnected
from the battery male connector while the battery
charger is switched on, an arc is produced. This can
lead to erosion at the contacts, which considerably
shortens the service life of the contacts.
–
Switch off the battery charger before disconnect-
ing the charging cable.
–
Switch off the battery charger.
–
Disconnect the battery male connector from
the plug for the battery charger.
–
Insert the battery male connector fully into
the plug connection on the tow tractor.
Checking the battery charge sta-
tus and calibrating the battery
charge indicator
CAUTION
Deep discharges shorten the service life of the bat-
tery.
Deep discharge begins when the battery charge dis-
play is red (3) (0% of the available battery capacity,
i.e. approx. 20% of the nominal capacity).
–
Deep discharge must be avoided (see the section
entitled "Equalising charge to prevent a deep dis-
charge of the battery").
–
Immediately stop working with the industrial truck.
–
Charge the battery immediately.
–
Do not leave batteries in a discharged or partly
discharged state.
–
Apply the parking brake.
–
Switch on the industrial truck.
–
Read the charge status on the display of
the display-operating unit.
–
Charge a discharged or partly discharged
battery.
Meaning of the colours in the display
1
Green:
The battery is sufficiently charged
2
Yellow:
Operation
4
Handling the lead-acid batteries
210
50078078001 EN - 07/2022 - 04
Summary of Contents for LXT 120
Page 2: ......
Page 12: ......
Page 13: ...1 Foreword ...
Page 37: ...2 Safety ...
Page 59: ...3 Overviews ...
Page 62: ...Overviews 3 Display control unit 50 50078078001 EN 07 2022 04 ...
Page 63: ...4 Operation ...
Page 265: ...5 Maintenance ...
Page 285: ...6 Technical data ...
Page 323: ......