23-4
Computer Link
23
*1 When the termination code is 08
(H)
(received an error response), the error code is contained in the
appended information. (Example: 0A
(H)
on a Sharp PC = parity error)
*2 Measurement number when outputting the results
00
(H)
= Measurement 0, Camera 1, 01
(H)
= Measurement 0, Camera 2, 02
(H)
= Measurement 1,
03
(H)
= Measurement 2, 04
(H)
= Measurement 3, 05
(H)
= Measurement 4
*3 Result output (Y0 to Y15)
*4 Measurement program for measurement 0
00
(H)
= none, 01
(H)
= positional deviation measurement
*5 Measurement programs for measurements 1 to 4
00
(H)
= none, 01
(H)
= positional deviation measurement, 02
(H)
= degree of match inspection, 03
(H)
=
lead inspection, 04
(H)
= BGA/CSP inspection, 05
(H)
= area measurement by binary conversion,
06
(H)
= object counting by binary conversion, 07
(H)
= object identification by binary conversion, 08
(H)
= point measurement, 09
(H)
= multiple positional measurement, 0A
(H)
= multiple degree of match
inspections, 0B
(H)
= fault inspection, 0C
(H)
= color evaluation, 0D
(H)
= color unevenness inspection,
0E
(H)
= color positional measurement.
*6 Output data from measurements 0 to 4 (block 0)
The data output will vary according to whether "ANY" or "BLOCK-ASSIGN" was selected on the
SERIAL OUTPUT item.
-
Pages 21-25 to 21-29.
When a block is specified
- The measurement data from measurement numbers 0 to 4 in block 0 is output. (Max. 496
bytes).
- Measurement numbers that have not been specified will not output any data. (The space will
be filled by the next item. Max. 500 bytes.)
- See pages 23-6 to 23-17, for details about the measurement data in block 0.
When "ANY" is selected for the output
See page 23-18.
*7 Assigned block data
When the SERIAL OUTPUT item is set to "BLOCK-ASSIGN," the IV-C35M will output the
measurement result data in the specified block number. When the SERIAL OUTPUT item is set
to "ANY," the nature of the output will depend on the output settings.
For details about how to specify measurement output, see pages 21-25 and 21-27.
- No data is output if block 0 (00) is specified.
For details about the measurement data block, see pages 23-5 to 23-17.
- The top address where the specified block of data is written will be an address made by
adding 512 bytes to the top address for writing results.
7
Bit
6
5
4
H (09005)
3
2
1
0
Y15 Y14 Y13 Y12 Y11 Y10 Y9 Y8
7
6
5
4
L (09004)
3
2
1
0
Y7 Y6 Y5 Y4 Y3 Y2 Y1 Y0
09000
09001
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
D0000
DM0000
D0256
DM0256
19000
19001
L
H
L
H
L
H
L
H
Termination code
Appended information
L
H
L
H
Assigned block data
Sharp
Mitsubishi
OMRON
Contents
Top address
for writing
results
Top address
for writing
results
+ 512 bytes
D00001
D00257
Yokogawa
.
.
.
L
H
L
H
L
H
Output data from
measurement 4 (block 0)
.
.
.
.
.
.
.
.