7-7
BGA/CSP Inspection
7
1
REGISTER NO.
2
CONDITION SET
3
NUMBER5 OF OBJ
4
TOTAL AREA
5
OBJECT AREA
6
X DIRECT SPACE
7
Y DIRECT SPACE
8
X FILLET WIDTH
9
Y FILLET WIDTH
0
TEST
COLOR F C1 BRT
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE01
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-DEVIATION
MEAS01(INSPECT-BGA/CSP F)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
+
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
○
1
WINDOW
BINARY-IMG-MASK
2
REGISTER NO.
0
3
REGISTER EXIST
YES
4
MASK BINARY IMG
REF-IMG
5
BIN IMG MASK
(TO NEXT SUB-MENU)
REGISTER NO.
6
BIN AREA COND
MEA-CND
SCREEN
COND
SAVE
RED F C1 BRT
IMG PRE-PROC
REG COND
EVALUATION
NUM-CALC
OUT
Measurement area
(Rectangle)
Mask area
(Rectangle)
- The inside of the measurement area
(excluding the mask area) is converted to
binary data.
BOUNDARY PROCESS
Select whether objects crossing the boundary of the window will be "VALID" or "INVALID."
For details, see page 3-22.
AREA FILTER
This function is used to exclude an object from measurement if its area is outside of the
upper or lower limits. Specify a number from 0 to 245760.
Example of register measurement are and area mask
Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu
on the "MEA-CND" (or "REG COND")
screen and press the SET key. Select
"EVALUATION" on the pop up menu to go
to the "EVALUAT COND" screen.
2) Move the cursor to the "EVALUATION
COND" item on the menu tree screen and
press the SET key.