21-30
Setting the Input/Output Conditions
21
21-8 Calibrating the IV-C35M
The IV-C35M calibration can be adjusted, e.g. "1 pixel = 1 mm", and the data can be displayed as
actual dimensions.
How to display the CALIBRATION setting screen
1) Select "MAIN COND" and then "OBJECT
TYPE COND."
2) On the "OBJECT TYPE COND" screen, move the cursor to any "TYPExx" that you want to
calibrate, and press the SET key.
3) Move the cursor to the "OBJ-TYPE I/O" line
and press the SET key.
4) On the "OBJ-TYPE I/O" screen, move the
cursor to the "
CALIBRATION" line and
from the popup menu, select "MANUAL."
Then, while the cursor is on the
"
CALIBRATION" line, press the SET key
twice to display a sub menu.
Note: Depending on settings for the "
TRIG
CCD START" and "
SERIAL
OUTPUT" items, the number of the
"CALIBRATION" line will vary between
and
.
5) Set the calibration details on the
"CALIBRATION" setting screen.
Put a ruler in the camera’s field of view .
COLOR F C1 BRT
CALIBRATION
SCREEN SAVE
1
CURSOR1-COORD
SET (256.240)
2
CURSOR2-COORD
SET (256.240)
3
SCALE
000.00
4
SCALE(UNIT)
mm
5
REG
EXEC
1PIXEL
CBP 000.0000 mm
1mm
CBM 000.0000 PIXEL
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
TYPE(NEW)
1
TRIG CCD START
2
FILTER TYPE
3
COLOR FILTER SET
4
CCD TRIG COND
5
SHUTTER SPEED
6
SERIAL OUTPUT
7
SET SERIAL BLOCK
8
CAM NO
9
CALIBRATION
0
FILTER TYPE
q
COLOR FILTER SET
w
CALIBRATION
COLOR F C1
BRT
SELECT OBJECT TYPE COND
+
+
1
TRIG CCD START
BIN
2
FILTER TYPE
RED
3
CCD TRIG COND
(TO NEXT SUB-MENU)
4
SHUTTER SPEED
1/00060 (1/30
〜
1/10000)
5
SERIAL OUTPUT
BLOCK-ASSIGN
6
SET SERIAL BLOCK
BLOCK00 MEAS0 CAM1
7
CAM NO
1 (1
〜
2)
8
CALIBRATION
MANUAL
9
CALIBRATION
(TO NEXT SUB-MENU)
RED F C1
BRT
OBJ-TYPE I/O
SCREEN SAVE
NO
MANUAL
EDGE DTECT
COLOR F C1 BRT
MAIN MENU
IVC35M
SYS-CND
OBJECT TYPE COND
SET WIZARD
EDIT MAIN OPS MENU
OPTION
ENVIRONMENT SETTING
MEMORY CARD