Lead Inspection
6-6
6
Ë
Ë
Ë
Ë
Ë
Example of settings
- Example when
4
DTECT MODE (detection mode) is set to "CENT (BRT)" (center dark) and
5
SEARCH DIRECT (search direction) is set to "HORIZ (horizontal)."
- Example when
4
DTECT MODE (detection mode) is set to "CENT (DRK)" (center dark) and
5
SEARCH DIRECT (search direction) is set to "HORIZ (horizontal)."
THRESHOLD
Specify a threshold value. Move the cursor to this line and press the SET key. The currently SET
item will be highlighted. Press the SET key again to enter the setting screen.
Move to each of the following items and press the SET key: "
GRYS." (difference of gray level)
"
EDGE.W" (edge width), and "
FLAT.W" (flat width). The current value for that item will be
highlighted and it can be changed using the up and down keys. After the value is correct, press
the ESC key to confirm it.
The values above can be reset to an appropriate level automatically. Move the cursor to the
upper function menu by pressing the TRG/BRT key and select "AUTO-REG". Then press the
SET key to set the levels automatically.
For details, see page 3-25.
EXTENSION MEAS,
EXT. MEAS DIRECT
Extension measurements can be made for "LEAD-LENGTH" or "BALL-WIDTH" in line "
EXTENSION MEAS. Then, the "
EXT. MEAS DIRECT" item will appear. At the "
EXT. MEAS
DIRECT" item, set the position for the extension measurement direction, relative to the reference
line.
Note: This line is only displayed when
"RECT" or "LINE" was selected for the
"DTECT SHAPE." To display this line,
move the cursor to the upper function
menu and select "DETAIL." Press the
SET key and select "EXTENSION
MEAS" from the popup menu. Then
press the SET key.
Edge
width
Flat
width
A
Brightness
Direction
B
Difference in
light
A
B
Edge
Reference line
Center point
A
Brightness
Direction
B
Edge
width
Flat
width
Difference in
light
A
Edge
B
Reference line
Center point
Reference line
Lead length
Decide the position using
"
8
EXT. MEAS DIRECT."
Measurement range
of lead length
RED F C1 BRT
OBJECT TYPE COND
SCREEN
COND
SAVE DENTAL
1
REGISTER NO.
00(0
〜
15)
2
DTECT SHAPE
RECT(ARTIFACT)
3
SEARCH AREA
SET(224,208)
〜
(287,271)
4
DTECT MODE
CENT(BRT)
5
SEARCH DIRECT
HORIZ(
→
)
6
THRESHOLD
SET(D:050 E:2 F:04)
□
EXTENSION MEAS.