21-1
Setting the Input/Output Conditions
21
Chapter 21: Setting the Input/Output Conditions
21-1 Outline
This section describes the input and output settings on the IV-C35M when connecting it for
communication with other equipment (a personal computer or a programmable controller).
How to display the "I/O CONDITIONS" setting screen
To display the "I/O CONDITIONS" screen, select
"MAIN COND" -> "SYS-CND" -> "I/O
CONDITIONS," in that order.
How to set the input and output conditions
The items you will need to set depend on whether
you selected "PUSB" or
"TRIG CCD START" on the "
MEAS INP I/F"
line.
When you want to select the " PARALLEL
+USB" on the "MEAS INP I/F" line.
MEAS INP I/F
Select "PUSB" for the
interface, in order to allow an external device
to provide trigger signals for the IV-C35M.
SYS-CND
I/O CONDITIONS
COMM.SET
COMPUTER LINK
GAIN-OFFSET
TIME
CAMERA TYPE
SELECT SYSTEM COND
COLOR F C1 BRT
1
MEAS INP I/F
2
OUT I/F(PARAL.)
3
MANL TYPE CHNG
4
PARALLEL INP X6
5
PARALLEL INP X7
6
STROBE OUT
7
’READY’ON
PUSB
TRIG CCD START
1
MEAS INP I/F
PUSB
2
OUT I/F(PARAL.)
NO
3
MANL TYPE CHNG
NO
4
PARALLEL INP X6
EXT-INP
5
PARALLEL INP X7
EXT-INP
6
STROBE OUT
NO
7
’READY’ON
CAPTURE COMPLETE
COLOR F C1 BRT
I/O CONDITION
SCREEN COND SAVE
CAPTURE COMPLETE
MEAS-COMPLETE
NO
PC-LINK
SERIAL
1
MEAS INP I/F
PUSB
2
OUT I/F(PARAL.)
NO
3
MANL TYPE CHNG
NO
4
PARALLEL INP X6
EXT-INP
5
PARALLEL INP X7
EXT-INP
6
STROBE OUT
NO
7
’READY’ON
CAPTURE COMPLETE
COLOR F C1 BRT
I/O CONDITION
SCREEN COND SAVE
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
EXT-INP
REG REF
COMRARE-IMGS
AREA EVAL CORECT
NO
YES
NO
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
EXT-INP
CHNG-IMG-OUT-CAM
CAM-MEAS