20-19
PC Function
20
20-6 PC monitor screen
Move the cursor to "SCREEN-CHG" on the
operation screen and press the SET key. A
popup menu will appear and you can select
"PC-MNTR" or "PC-MNTR 2", and press the
SET key. Then the PC monitor screen will be
displayed.
However, before you can display this screen,
you have to set "YES" on the "
PC-MNTR"
on the "TYPE RUN COND" screen.
See page 2-11.
The ON ( ) or OFF ( ) status of the input
relays (X00 to X07) is displayed.
The ON ( ) or OFF ( ) status of the output
relays (Y00 to Y15) is displayed.
The ON ( ) or OFF ( ) status of the
auxiliary relays (C000 to C127) is
displayed.
The results (AN00 to AN15) of the final
numerical calculations are displayed.
The current timer value is displayed.
The current counter value is displayed.
Menu bar
The other data displayed is the same as on the operation screen.
See page 1-10.
1
2
3
4
5
6
[
TMR
]
TM0:
NOT SET
TM1:
NOT SET
TM2:
NOT SET
TM3:
NOT SET
TM4:
NOT SET
TM5:
NOT SET
TM6:
NOT SET
TM7:
NOT SET
[
CNTR
]
CN0:
NOT SET
CN1:
NOT SET
CN2:
NOT SET
CN3:
NOT SET
CN4:
NOT SET
CN5:
NOT SET
CN6:
NOT SET
CN7:
NOT SET
COLOR F C1 DRK
V*.**
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
X00 〜 07 □□□□□□□□
Y000〜007 □□□□□□□□
READY■
C000〜007 □□□□□□□□
[
NUMERIC CALC
]
AN00
=
NOT SET
AN01
=
NOT SET
AN02
=
NOT SET
AN03
=
NOT SET
AN04
=
NOT SET
AN05
=
NOT SET
AN06
=
NOT SET
AN07
=
NOT SET
7
OPS-MAIN
PC-MNTR 2
Change the output
relay address
Change the
auxiliary relay
address
Change the final
numerical calculation
address
MNU-CHG MAIN-COND SEL-OUT SEL-AUX SEL-NUM SCREEN-CHG CHG-TYPE
Menu bar
SEL-OUT
Description
Change the output relay address (Y00 to Y15) with the up and down keys
(in units of 8 points).
SEL-AUX
Change the auxiliary relay address (C000 to C127) with the up and down
keys (in units of 8 points).
SEL-NUM
Change the final numerical calculation address (AN00 to AN15) with the up
and down keys (in units of 8 points).