12-7
Color Unevenness Inspection
12
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using the
left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from the
popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 19: Numerical calculation."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using the
left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the popup
menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 21: Setting the Input/Output Conditions."
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be displayed
on the screen.
COLOR F C1 BRT
V
*
.
**
(TYPE00)
OK
MEAS
0025ms
2002-02-04 16:13
MEASUREMENT
1
INSPECT COLOR SHADING
REGISTER NO. (0
〜
3)
K
= 015
OK
A
= 003700
OK
R = 003628
OK
000001
H = 155.8
OK
138.7
EH = 000000
OK
S
= 061.7
OK
042.7
ES = 000000
OK
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0
〜
7
Y0
〜
7
READY
Number of objects
Total area
Max. area
Min. area
Max. hue
Min. hue
Hue fault
Max. saturation
Min. saturation
Saturation fault