16-8
Multiple Degree of Match Inspection
1 6
1 6
1 6
1 6
1 6
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-CALC" from
the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 19: Numerical calculations."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND" using
the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT" from the
popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 21: Setting the Input/Output Conditions.
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be displayed on
the screen.
COLOR F C1 BRT
V*.**
(TYPE00)
OK
MEAS XXXXms
2001-10-14 10:38
MEASUREMENT 1 MULTI-MATCHES
REG.NO (0~3)
K=004
OK
DTECT NO.000(000~003)
M=+09870
OK
G=228.3
X=236.0
Y=163.0
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0
〜
7
□□□□□□□□
Y0
〜
7
□□□□□□□□
READY
□
Final evaluation result
Measuring time
Measuring program number
Register number
Number of detected images
Numbered in the order detected (range)
Degree of match
Detected coordinate
Light level (average/absolute value)
■
Display example