7-8
BGA/CSP Inspection
7
1
REGISTER NO.
0(0~3)
[TEST RESULT]
[OUTPUT]
2
CONDITION SET
AUTO(
±
10%)
3
NUMBER OF OBJ
000~128
K=
NO
4
TOTAL AREA
000000~245760 A=
NO
5
OBJECT AREA
000000~245760 R=
NO
6
X DIRECT SPACE
000.0~511.0
DX=
NO
7
Y DIRECT SPACE
000.0~479.0
DY=
NO
8
X FILLET WIDTH
000~511
FX=
NO
9
Y FILLET WIDTH
000~479
FY=
NO
0
TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
EVALUAT COND SCREEN COND SAVE EDIT SEL
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-28.
Numeric calculation setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND"
using the left and right arrow keys. Press the SET key to show the popup menu. Select "NUM-
CALC" from the popup menu.
- Select "NUM-CALC" on the menu tree.
See "Chapter 19: Numerical calculation."
Output condition setting
- Press the TRG/BRT key to move the cursor to the upper function menu, and highlight "COND"
using the left and right arrow keys. Press the SET key to display the popup menu. Select "OUT"
from the popup menu.
- Select "OUT-COND" on the menu tree.
See "Chapter 21: Setting the Input/Output Conditions."
Display the inspection results
Return to the operation screen and press the TRG/BRT key. The inspection results will be displayed
on the screen.
COLOR F C1 DRK
V*.**
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
MEASUREMENT 1 INSPECT BGA/CSP
REGISTER N00(0~15)
K=006
OK
A=008492
OK
R=001450
OK
001383
OK
DX=138.2
OK
136.4
OK
DY=409.6
OK
407.8
OK
FX=031
OK
030
OK
FY=031
OK
030
OK
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0
〜
7
□□□□□□□□
Y0
〜
7
□□□□□□□□
READY
■
□
NUMBER OF OBJ
TOTAL-AREA
OBJECT-AREA
(Max./Min. : Number of pixels)
X DIRECT SPACE
(Max./Min. : Number of pixels)
Y DIRECT SPACE
(Max./Min. : Number of pixels)
X FILLET WIDTH
(Max./Min. : Number of pixels)
Y FILLET WIDTH
(Max./Min. : Number of pixels)
[Display of the inspection results]
Final evaluation result
Measuring time
Measurement program number
Registration number of
measurement condition