1-30
Setting and Operating Outline
1
Item
Specifications
Color evaluation
Area, hue (average), saturation (average), color degree of match
[Maximum 8 windows ]
Color unevenness
inspection
Number of objects [Maximum 128 windows ]
Total area, hue (max./min.), number of faults of hue, saturation (max./min.), and
number of faults of saturation. [Maximum 4 windows ]
Color position
measurement
XY coordinate, XY deviation amount, color degree of match (1-point search, 2-point
search, 1-point edge, 2-point edge, 1-point search and 1-point edge)
[Maximum 8 windows x 2 models]
Fault inspection
Density (max./min.), density difference (max.)
[Maximum 8 windows ]
Positional deviation
measurement
XY coordinate, deviation amount in X and Y axes, degree of match (1-point search, 2-
point search, 1-point edge, 2-point edge, 1-point search and 1-point edge)
Angle: ±15 , ±30 , ±45 , 360 (1-point search, 1-point 1-point edge)
[Maximum 8 windows x 2 models]
Degree of match
inspection
Degree of match, XY coordinate, density (1-point search, 2-point search)
[Maximum 16 windows x 2 models]
Area measurement
by binary conversion
Area [Maximum 16 windows]
Object counting by
binary conversion
Quantity (maximum 3,000 items per window), total area [Maximum 4 windows]
Object identification
by binary conversion
Quantity (maximum 128 per window), total area, area of each object identified, gravity
center, main axis angle, fillet diameter, peripheral length, center point
[Maximum 4 windows]
Point measurement Number in binary image (maximum 256 points), average density [Maximum 128 points]
Lead inspection
Number of leads, distance between leads (max., min.), lead width (max., min.), lead
length (max., min.)
[Maximum 16 windows]
BGA/CSP inspection
Number of labels, total area, area of each label, XY pitch (max., min.) XY fillet diameter
(max., min.), [Maximum 4 windows ]
Multiple positional
measurement
Number of objects (max. 128), degree of match, XY coordinate (1-point search, 1-point
edge)
[Maximum 4 windows]
Multiple degree of
match inspection
Number of objects (max. 128), degree of match, XY coordinate (1-point search)
[Maximum 4 windows]
Number of measurement
programs
Maximum 6 per object type (measurement 0 - camera 1, measurement 0 - camera 2,
measurements 1 to 4)
Note: Measurement 0 is only used for positional deviation measurement.
Window shape
Rectangle, circle, oval (when using color evaluation, color unevenness inspection, area
measurement by binary conversion, object counting by binary conversion, object
identification by binary measurement), circumference (when using fault inspection), and
arc (when using fault inspection).
Distance and angle
measurement
Measure distance (between two points, X coordinate, Y coordinate), measure angle (3
points, 2 points against horizontal line, 2 points against vertical line), auxiliary point
(center, circle center, gravity center, line over 2 points, crossing point of two straight
lines)
Arithmetic operation
Four basic operations (+, -, X, /), root, absolute value, TAN, ATAN, maximum,
minimum, average , total.
NG image memory
function
Maximum 128 images (8 images for all images)
Possible extension when using a memory card (compact flash memory)
Memory card slot
One slot (compatible card : up to 192 MB)
Calendar/timer
Year, month, day, hour, minute
Other functions
Display measuring time, light level monitor function, crosshair cursor display, change
display language between Japanese and English, Run screen lock function, setting
menu display "yes/no", change image display (through/freeze), change image
brightness (bright/dark)
Input relays
Parallel input: 8 points (X0 to X7)
Output relays
Parallel output: 8 points (Y0 to Y7)
General-purpose serial interface, computer link: 16 points (Y0 to Y15)
Auxiliary relays
128 points (C000 to C127), special area 18 points (C110 to C127)
Timers
8 points (TM0 to TM7), timer setting range: 0.01 to 9.99 seconds (countdown timer)
Counters
8 points (CN0 to CN7), counter setting range: 000 to 999 (counts down)
Measurement program
Micro PLC
section