2-10
Setting the Operating and System Conditions
2
[8] Evaluation change display
Specify whether the evaluation condition change
menu can be displayed on the operation screen or
not.
Select the "
DISP CHG-EVAL" line on the "TYPE
RUN COND" screen and select "YES" on the popup
menu.
Press the TRG/BRT key to move the cursor to the
upper function menu. Select "SCREEN" and press
the SET key. Then select "OPS-MENU."
Select "SCREEN-CHG" on the lower menu on the
operation screen, and press the SET key. "JDG-
COND CHG" will be displayed in the lower right
corner of the screen. You can display the evaluation
condition change menu by pressing the up and down
keys.
- Press the SET key. The cursor will move to the
area containing the phrase "evaluation condition
change menu during operation." You can change
the settings for the evaluation conditions.
- At this time, the screen display will look the same
as the normal operation main screen, except for the
area marked "evaluation condition change menu
shown during operation."
1
MONITOR OUTPUT
CAM1
2
CAPTURE IMG
PARTIAL-IMG
3
MESSAGE DISPLAY
YES(NUMERIC)
4
PATTERN DISPLAY
YES
5
SHOW BINARY IMG
YES
6
SHOW
θ
FIX IMG
YES
7
OPS MAIN DISP
YES
8
DISP CHG-EVAL
YES
9
PC-MNTR
NO
0
THROUGH DISPLAY
NO
q
EXTENSION FUNC.
NO
TYPE RUN COND SCREEN SAVE
COLOR F C1 BRT
SET=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
YES
NO
1
MONITOR OUTPUT
CAM1
2
CAPTURE IMG
PARTIAL-IMG
3
MESSAGE DISPLAY
YES(NUMERIC)
4
PATTERN DISPLAY
YES
5
SHOW BINARY IMG
YES
6
SHOW
θ
FIX IMG
YES
7
OPS MAIN DISP
YES
8
DISP CHG-EVAL
NO
9
PC-MNTR
NO
0
THROUGH DISPLAY
NO
q
EXTENSION FUNC.
NO
TYPE RUN COND SCREEN SAVE
COLOR F C1 BRT
OPS-MENU
MAIN
SELECT
RETURN
X0〜7 □□□□□□□□ Y0〜7 □□□□□□□□ READY
■
□
(TYPE00)
COLOR F C1 BRT
MEAS 0000ms 2001-10-14 10:38
MEASURE 0 CAM1 POSI-DEVIATION
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
JDG-COND-CHG
PC-MNTR
PC-MNTR 2
Display evaluation condition
change menu while in operation