22-11
Communication (General Purpose Serial Interface)
22
(5) Illuminance level reading: code 28
(H)
The illuminance level measured by the illuminance monitor function and the evaluation result are
read.
- Camera No.
→
0: camera 1, 1: camera 2
- Object type
→
Object type for which the measurement was executed: 00 to 0F
- Result
→
0: NG, 1: OK
- Illuminance
→
000.0 to 255.0
Ë
Response
:
2 8
RC
(H)
RC
(L)
Illuminance
10
2
10
1
10
0
10
-1
SC
(H)
SC
(L)
CR
Result
:
2 8
SC
(H)
SC
(L)
Ë
Command
CR
Object
type
Station
No.
Station
No.
Execution
camera
(6) Corrected light level reading: code 29
(H)
The corrected light level measured by the illuminance monitor function, the evaluation result and
preset reference light level are read.
- Object type
→
Object type for which the measurement was executed: 00 to 0F
- Result
→
0: NG, 1: OK
- Corrected light level
→
Corrected light level (
–
0 to 255.0)
- Reference light level
→
Light level used as the criterion (0 to 255.0)
Ë
Response
:
2 9
RC
(H)
RC
(L)
Corrected
light level
Reference
light level
±
10
2
10
1
10
0
10
2
10
1
10
0
10
-1
10
-1
SC
(H)
SC
(L)
CR
Result
:
2 9
SC
(H)
SC
(L)
Ë
Command
CR
Object
type
Station
No.
Station
No.
Execution
camera
- Camera No.
→
0: camera 1, 1: camera 2