16-7
Multiple Degree of Match Inspection
1 6
1 6
1 6
1 6
1 6
Set the evaluation conditions
How to move to the evaluation condition setting screen
There are two methods for getting to the evaluation condition setting screen.
1) Select "COND" in the upper function menu on
the "MEAS COND (or REG COND)" screen
and press the SET key. Select
"EVALUATION" on the pop up menu to go to
the "EVALUAT COND" screen.
2) Move the cursor to the "EVALUATION COND"
item on the menu tree screen and press the
SET key.
The "EVALUAT COND" (evaluation conditions)
screen will appear.
For details about the evaluation conditions,
see page 3-28.
MEAS CND
SCREEN
COND
SAVE
1
DTECT PRECISION
STANDARD
2
REGISTER NO.
0(0~3)
3
MODE
YES
4
MATCHING
AVG-GRAYS
5
DETECT ORDER
SCAN-ORDER
REGISTER NO.
6
DTECT OBJECT
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
×
S
× ×
RED F C1 BRT
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
IMG PRE-PROC
REG-COND
EVALUATION
DST&ANGL
NUM-CALC
OUT
1
REGISTER NO.
0COND.1
[TEST RESULT]
[OUTPUT]
2
CONDITION SET
AUTO(
±
10%)
3
NUMBER OF OBJ
000~128
K=
NO
4
DTECT NUMBER
000(0~000)
5
MATCH LVL
-10000~+10000 M0=
NO
6
GRAY LVL
000.0~255.0
G0=
NO
X COORD.
X0=
Y COORD.
Y0=
7
TEST
EXEC(WITH-POSI.ADJ WITHOUT-POSI.ADJ)
SET=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
EVALUAT COND SCREEN COND SAVE EDIT SEL
COLOR F C1 BRT
SELECT OBJECT TYPE COND
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS01(MULTI MATCHES F)
IMG PRE-PROC
MEAS CND
REG-COND
EVALUATION COND
DISTANCE&ANGLE COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
SET=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
+
1
REGISTER NO.
2
CONDITION SET
3
NUMBER OF OBJ
4
DTECT NUMBER
5
MATCH LVL
6
GRAY LVL
7
TEST