14-9
Point Measurement
14
When MODE has been set to BINARY
When MODE has been set to AVG-GRAYS
COLOR F C1 DRK
V*.**
(TYPE00)
OK
MEAS XXXXms
MEASUREMENT 1 POINT-MEAS
P000=WHITE OK
P001=WHITE OK
P002=WHITE OK
P003=WHITE OK
P004=WHITE OK
P005=
P006=
P007=
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0〜7
Y0〜7
READY
COLOR F C1 DRK
V*.**
(TYPE00)
OK
MEAS XXXXms
MEASUREMENT 1 POINT-MEAS
P000=115 OK
P001=120 OK
P002=114 OK
P003=118 OK
P004=116 OK
P005=115 OK
P006=
P007=
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0〜7
Y0〜7
READY
Final evaluation result
Measuring time
Measurement program number
Evaluation of the correct black or white
color detected at registration No.000
001
002
003
004
005
006
007
- Areas will not be displayed for
unspecified registration numbers.
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be displayed
on the screen.