21-28
Setting the Input/Output Conditions
21
21-7 Setting the data output
When you communicate with the IV-C35M using a computer link or a serial communication interface
(general purpose serial IF) in the following conditions, perform steps (1) and (2) below to enable serial
output.
- Computer link: When outputting any data
Pages 23-3 and 23-4.
- Communication interface (general purpose serial IF): When executing a measurement run command
4 (processing code 14
(H)
) and 4 (processing code 24
(H)
)
Pages 22-8 and 22-10.
[1] Select "ANY" for the serial output
Select "ANY" in the "
SERIAL OUTPUT" item on the "OBJECT TYPE I/O" screen.
Setting (operating) procedure
1. Select "MAIN COND" -> "OBJECT TYPE
COND" -> "TYPE00" -> "OBJ-TYPE I/O" in
that order.
2. The "OBJ-TYPE I/O" screen will appear. Move
the cursor to "
SERIAL OUTPUT" and press
the SET key. A popup menu will appear.
Select "ANY" and press the SET key.
1
TRIG CCD START
BIN
2
FILTER TYPE
RED
3
CCD TRIG COND
(TO NEXT SUB-MENU)
4
SHUTTER SPEED
1/00060 (1/30
〜
1/10000)
5
SERIAL OUTPUT
ANY
6
CAM NO
1 (1
〜
2)
7
CALIBRATION
MANUAL
8
CALIBRATION
(TO NEXT SUB-MENU)
RED F C1
BRT
OBJ-TYPE I/O
SCREEN SAVE
SET
=SELECT A MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
ANY
BLOCK-ASSIGN
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/O
OBJ-TYPE SYS.
TYPE(NEW)
1
TRIG CCD START
2
FILTER TYPE
3
COLOR FILTER SET
4
CCD TRIG COND
5
SHUTTER SPEED
6
SERIAL OUTPUT
7
SET SERIAL BLOCK
8
CAM NO
9
CALIBRATION
0
FILTER TYPE
q
COLOR FILTER SET
w
CALIBRATION
COLOR F C1
BRT
SELECT OBJECT TYPE COND
SET
=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+