2-13
Setting the Operating and System Conditions
2
(2) Manual measurement
With this function, you can measure distance between two points, the distance between X
coordinates, or the distance between Y coordinates that were selected manually on the operation
main screen.
Operation procedure
1. Select "
EXTENSION FUNC." on the
"TYPE RUN COND" screen using the up
and down arrow keys. Then press the SET
key.
2. Select "MANL-MEAS" on the popup menu
and press the SET key.
3. Move the cursor to the upper function menu
by pressing the TRG/BRT key and select
"SCREEN." Then press the SET key.
Select "OPS-MENU" on the popup menu
and return to the operation screen.
4. Move the cursor to the "MNU-CHG"
(menu change) item on the bottom of
the operation screen and press the
SET key to change the bottom menu
display. Move the cursor to "MANL-
MEAS" (manual measurement) and
press the SET key.
5. The menu items for manual
measurements will appear on the
screen.
6. Select "
CURSOR1-COORD" or "
CURSOR2-COORD" and press
the SET key.
7. Move cursor 1 or cursor 2 using the
up/down/left/right keys. (They move
one pixel at a time.)
The distance between the two
points, and between the X
coordinates and Y coordinates
for the two points, will change on
real time basis.
8. After the positions of the points are determined, press the SET key.
9. When the operation is complete, press the ESC key.
The manual measurement menu items will disappear.
1
MONITOR OUTPUT
CAM1
2
CAPTURE IMG
PARTIAL-IMG
3
MESSAGE DISPLAY
YES(NUMERIC)
4
PATTERN DISPLAY
YES
5
SHOW BINARY IMG
YES
6
SHOW
θ
FIX IMG
YES
7
OPS MAIN DISP
YES
8
DISP CHG-EVAL
NO
9
PC-MNTR
NO
0
THROUGH DISPLAY
NO
q
EXTENSION FUNC.
MANL-MEAS
TYPE RUN COND SCREEN SAVE
COLOR F C1 BRT
NO
CURSOR
MANL-MEAS
1
MONITOR OUTPUT
CAM1
2
CAPTURE IMG
PARTIAL-IMG
3
MESSAGE DISPLAY
YES(NUMERIC)
4
PATTERN DISPLAY
YES
5
SHOW BINARY IMG
YES
6
SHOW
θ
FIX IMG
YES
7
OPS MAIN DISP
YES
8
DISP CHG-EVAL
NO
9
PC-MNTR
NO
0
THROUGH DISPLAY
NO
q
EXTENSION FUNC.
NO
TYPE RUN COND SCREEN SAVE
COLOR F C1 BRT
OPS-MENU
MAIN
SELECT
RETURN
OK
X0〜7
Y0〜7
READY
(TYPE00)AREA1
MEAS
XXXX
ms 2002-10-14 10:38
MEASURE 0 CAM1 POSI DEVIATION
MANL-MEAS
1
CURSOR1-COORD MOVE(224,208)
2
CURSOR2-COORD MOVE(287,271)
DIST-BETW-2PT 089.0
DIST-BETW-X
063.0
DEST-BETW-Y
063.0
MNU-CHG NEXT-NG CHG-C1 CHG-C2 MANL-MEAS SHORTCUT
Crosshair cursor 1
Crosshair cursor 2
Manual measurement
menu