Setting Measurement Conditions
3-8
3
3. Press the SEL key to move the cursor to the
"F" (freeze image) that is at upper right of the
screen. Press the up and down arrow keys to
change from "F" to "T" (through image). The
image of Camera 1 changes to through image
and current image through the camera dis-
played on the monitor.
Change the image from "T" to "F" using the up
and down arrow keys. By changing the image
from "T" to "F," the IV-C35M stores the image.
4. On the "REG COND" screen, select
"
REFIMG ARE" and enter the RECT-
ANGLE setting screen.
5. Determine "
UP.L" and "
LO.R" to specify
the position and size of the rectangle, select
the "
REFERENCE IMG" and press the SET
key. On the popup menu, select the "REG"
and the selected range appears at the lower
right of the screen.
SET
=VALUE INPUT ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
REG COND SCREEN COND SAVE DETAIL
1
REGISTER NO
0 (0
〜
7)
2
MEAS SHAPE (MDL0)
RECTANGLE
3
REF IMG ARE (MD
L0)
SE
T
(224, 208)
〜
(287, 271)
4
SEARCH ARE (MD
L0)
SE
T
(216, 200)
〜
(295, 279)
SET
=MOVE ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
RECTANGLE RESET RETURN
X:224 Y:208
CONTRAST SRCH
REG
DISP
1
UP. L
(224, 208)
2
LO. R
(287, 271)
3
MOVE
4
REFFERENCE IMG
1
UP. L
(224, 208)
2
LO. R
(287, 271)
3
MOVE
4
REFFERENCE IMG
SET
=DECISION ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
RECTANGLE RESET RETURN
X:224 Y:208
MDL 0