17-4
Fault Inspection
17
3) On the menu tree, move the cursor to the
"MEAS CND" item, and press the right
arrow key. The sub menu which contains
the "REG COND" item will appear. Move
the cursor to either of these items and
press the SET key.
REGISTER NO.
Enter a number to register the specified
measurement conditions. To change the
number, highlight the number and press the
up and down arrow keys.
MEAS SHAPE
Select the shape of a measurement area.
MEAS AREA
Specify measurement area according to the
shape specified above.
- When "RECTANGLE" is selected
Specify upper left and lower right corners.
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEAS0
POSI-CORRECT
MEAS01 (POSI-DEVIATION F)
MEAS02 (INSPECT NG F)
IMG PRE-PROC
MEAS CND
REG COND
EVALUATION COND
NUM-CALC
OUT-COND
MEAS(NEW)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
1
REGISTER NO.
2
DEFFERENCE COLOR
3
MEAS SHAPE
4
CELL SIZE
COLOR F C1
BRT
SELECT OBJECT TYPE COND
SET
=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
+
+
RECTAN-
GLE
Measures inside a rectangle
between its specified upper left
and lower right corners
CIRCUM-
FERENCE
Measures along the specified
circumference line.
ARC
Measures along the specified
arc from the start to end points.
1
REGISTER NO.
0 (0
〜
7)
2
MEAS SHAPE
RECTANGLE
3
MEAS AREA
SET (224, 208)
〜(287, 271)
4
CELL SIZE
16 (4
〜96)
SET
=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
REG CND
SCREEN COND SAVE
RECTANGLE
CIRCUMFERENCE
ARC
1
UP. L
(224, 208)
2
LO. R
(287, 271)
3
MOVE
SET
=MOVE ESC=BACK SEL=CHNG IMG TRG=FUNC
RED F C1 BRT
RECTANGLE
RESET
RETURN
X: 224 Y: 208