1-17
Setting and Operating Outline
1
1-8 Register and display NG images
NG image refers to any image that the controller has determined to be unacceptable after making the
measurements.
- NG images are registered in the controller’s memory. By replaying the NG images, you can review the
points with problems.
This section describes how to register, display, and initialize NG images.
[1] How to register NG images
When the IV-C35M is used, select "YES" for NG image registration. NG images will be registered in the
controller’s memory as they occur.
To make this setting, select "
REGST NG IMG" on the [OBJ-TYPE SYS.] menu.
See page 3-52.
NG screen setting procedure
On the "SELECT OBJECT TYPE COND" screen,
select "MEA-CND (CAMERA2)" and press the TRG/
BRT key. From the popup menu, select "NG IMGS"
and press the SET key.
When the message shown on the right appears,
press the SET key.
SET
=TO NEXT SUB-MENU ESC=BACK SEL=CHNG IMG TRG=POPUP
COLOR F C1 BRT
OBJECT TYPE COND
TYPE00
TYPE RUN COND
IMAGE-ADJ
MEA-CND(CAMERA1)
MEA-CND(CAMERA2)
FINAL NUM. CALC
FINAL OUTPUT COND
OBJ-TYPE I/0
OBJ-TYPE SYS.
TYPE(NEW)
SELECT OBJECT TYPE COND
+
OPS-MENU
SAVE
NG IMGS
BY CHANGING A SETUP, THE CONTENTS OF SETTING IN A
CAMERA 2 WILL BE INITIALIZED. DO YOU CHANGE IT?
YES=SET, NO=ESC
Item
Reference page
Register NG images
1-17
NG images
display
MAIN OPS
menu
screen
Display when
an NG image
occurs
1-19 to 1-21
Display history 1-21
NG image display screen
1-22
Initialize NG images
1-23