8-9
Area Measurement by Binary Conversion
8
Display the measurement results
Return to the operation screen and press the TRG/BRT key. The measurement results will be displayed on
the screen.
COLOR F C1 BRT
V*.**
(TYPE00)
OK
MEAS XXXXms 2001-10-14 10:38
MEASUREMENT 1 MEAS-BIN-AREA
A00=005253
OK
A01=002674
OK
A02=003200
OK
A03=001884
OK
A04=
A05=
A06=
A07=
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
X0〜7□□□□□□□□ Y0〜7□□□□□□□□ READY
■
□
*
*The areas will not be displayed
for any unspecified registration
numbers.
Final evaluation result
Measuring time
Measurement
program number
Area for registration number 00 in the
measurement condition (Number of pixels)
" 01
" 02
" 03
" 04
" 05
" 06
" 07