![background image](http://html1.mh-extra.com/html/omron/f3sg-pg-series/f3sg-pg-series_user-manual_741299113.webp)
83
F3SG-SR/PG
User’s Manual
Chapter
2
Mu
ti
ng
System Operation and Functions
E
3.
MUTING is maintained
The F3SG-SR/PG C1 and C2 are blocked but the safety function is disabled due to MUTING, and the
OSSD 1 and 2 are turned ON.
4.
MUTING is released
The muting sensor A1 is turned OFF, the Muting state is released, and the safety function of the F3SG-
SR/PG C1 and C2 is enabled.
Installation distance
The minimum distance, D1 [m], required for muting sensors to keep MUTING enabled is :
D1 < L . . . . . Formula (1)
L [m]: Length of a workpiece
The maximum distance, d1 [m], required for muting sensors to keep the MUTING state enabled is :
V x T1min < d1 < V x T1max . . . . . Formula (2)
V [m/s]: Approach speed of a workpiece
T1min [s]: Muting input time limit value (minimum). It is set as 0.1 s. It can be changed.
T1max [s]: Muting input time limit value (maximum). It is set as 4 s. It can be changed.
To enable the MUTING state, D1 and d1 must satisfy formulas (1) and (2), respectively.
W
orkpiece
C1
C2
B1
Mirror
Mirror
A1
Hazardo
u
s zone
W
orkpiece
C1
C2
B1
Mirror
Mirror
A1
Hazardo
u
s zone
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...