14
Chapter
1
LED Indica
tor
s
on F3SG-SR/PG
F3SG-SR/PG
User’s Manual
Overview and Specifications
*1. Refer to
for more information on blinking patterns.
*2. Configurable by SD Manager 3.
*3. This is the case for the Standard Muting mode. For other muting modes, refer to
.
*4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
*5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
*6. DIP switches is on the Intelligent Tap.
In the SETTING state to make settings with the SD Manager 3, the TEST, LONG and CODE indicators on the emitter
and the CFG, PNP and CODE indicators on the receiver blink.
(TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green)
For more information on the statuses of the LED indicators in the SETTING state, refer to
of F3SG-SR/PG with SD Manager 3 Connected
8
-
Area
Beam
Indicator
(ABI)
Green
The target beams of the
ABI are unblocked and
the safety outputs are
turned ON
MUTING or OVERRIDE state. In the
MUTING state, only the ABI
indicators in the muting zone are
blinking. Or the target beams of the
ABI are blocked instantaneously
X
-
Orange
Incident light level of the
target beams of the ABI
is 170% (factory default
setting (*2)) or less of
ON-threshold (for 5 to 10
s)
Incident light level of the target beams
of the ABI is 170% (factory default
setting (*2)) or less of ON threshold 5
to 10 s after illuminated when incident
light level of the target beams of the
ABI is 170% (factory default setting
(*2)) or less of ON threshold. Or one
muting input becomes the ON state
and the MUTING state has not been
started yet, or one muting input
becomes the OFF state and the other
is not in the OFF state yet. (*3)
Red
The target beams of the
ABI are blocked
LOCKOUT state due to Cap error or
Other sensor error (*4), or LOCKOUT
state due to DIP Switch setting error
(*5 *6)
OFF
The target beams of the
ABI are unblocked (The
ABI then will be
illuminated in green when
the safety outputs are
turned ON.)
-
9
TOP
Top-beam-
state
Blue
The top beam is
unblocked
MUTING/OVERRIDE state, or
LOCKOUT state due to Cap error or
Other sensor error
-
X
10
BTM
Bottom-
beam-
state
Blue
The bottom beam is
unblocked
MUTING/OVERRIDE state, or
LOCKOUT state due to DIP Switch
setting error (*6)
-
X
Location Indicator
Name
Color
Illuminated
Blinking
F3SG-
SRA
F3SG-
SRB
F3SG-
PG
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...