To finish the maintenance task and start normal operation of the facility,
perform the followings.
1.
Use a Phillips screwdriver to attach the cover of the intelligent tap.
(Recommended tightening torque: 0.35N
m)
2.
If a cable is not attached to CN3, use the torque wrench XY2F-0004 to attach the accessory
waterproof cover (for plug).
(Recommended tightening torque for waterproof cover (for plug): 0.39 to 0.49N
m)
3.
If a cable is not attached to CN4, attach the accessory waterproof cover (for socket).
3-10-2.
Saving Sensor Setting to Intelligent Tap Using Backup
Function
You can use the backup function to save to the intelligent tap the same settings as setup information
stored in F3SG-SR/PG. To apply the saved setting to another F3SG-SR/PG, refer to
Setting Saved in Intelligent Tap to Sensor Using Restoration
Work steps
1.
If power of the intelligent tap or F3SG-SR/PG is ON, turn it OFF.
2.
Use a Phillips screwdriver to remove the cover of the intelligent tap.
3.
Set the DIP-SW channels 1 to 8 OFF.
DIP-SW
1
2
3
4
5
6
7
8
O
N
Push-SW
DIP-SW
Bluetooth
®
Communication Unit
Connector
USB Type-C
TM
Connector
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...