168
Ch
apt
e
r
3
Tea
c
h-
in
(F
ix Bla
n
king / Flo
a
ting
Blank
in
g
)
F3SG-SR/PG
User’s Manual
Setting with Intelligent Tap
(3) DIP Switch Setting
Before powering the F3SG-SR, set the DIP Switch of the intelligent tap as shown below, then power
the F3SG-SR.
• Set channel 1 to ON (Lock)
• Set channel 2 to ON (DIP Switch Enabled)
• Set channel 6 to ON and channel 7 to OFF (Fixed Blanking Enabled)
The Intelligent Tap restores the settings configured by the DIP Switch, to the F3SG-SR. When the
Restoration process is complete successfully, restart the F3SG-SR and check if the F3SG-SR
operates normally.
Block the target Fixed Blanking zone by an object. Do not remove the object until the Step (5) is
complete.
Refer to
3-4. LED Indicators on Intelligent Tap
for more information.
(4) Transition to Teach-in Mode
Under the factory default setting, pressing and holding the Push Switch (for 3 s or longer) makes the
product transition to Teach-in mode.
When the F3SG-SR transitioned to Teach-in mode, the CFG indicator of the F3SG-SR receiver blinks.
(The mode transition to Teach-in mode does not occur if the setting of the DIP Switch is configured as
"Unlock", "DIP Switch Disabled" or "Fixed Blanking Disabled".)
The factory default setting of the Teach-in Input is [Enable Teach-in by Push Switch]. When selecting [Enable Teach-in by
Push Switch or wiring], select [Teach-in Input] – [Enable Teach-in by Push Switch or wiring] with the SD Manager 3 after
the step (2), and then perform the Restoration.
The [Enable Teach-in by Push Switch or wiring] function cannot be used in combination of some functions. Refer to 2-1.
Combination of Functions for more information on combinations of functions.
Refer to
for more information on setting this function by the SD Manager 3.
Refer to
4-2-7-3. Writing Configuration into Intelligent Tap
for more information on the Restoration by the SD Manager 3.
Indicator status of the F3SG-SR receiver under the Teach-in mode.
*1 If F3SG-SRA is used with the wired synchronization setting, the ABI indicator of the emitter for the area blocked by an object
turns ON red.
(5) Teach-In and Check Processes
When it is ensured that the F3SG-SR is in the Teach-in mode, press the Push Switch (for within 1 s) or
turn the muting input A ON (for within 1 s) to activate the scanning of the blocked area and
automatically configure the setting related to the Fixed Blanking.
*1
The F3SG-SR judges if the setting is valid or not.
If the setting is invalid
*2
, SEQ indicator of the receiver blinks. In this case, try the steps again from (4).
LED Indicator
Status
SEQ
CFG
ABI *1
Area blocked by
blocking object is
illuminated in red
OFF
Blinking
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...