System Operation and Functions
Constraint between fixed blanking zones
More than one fixed blanking zone can be configured adjacently (Figures 1 and 2). But allowable
beams cannot be set adjacently (Figure 3). You cannot overlap fixed blanking zones. (Figure 4)
Limitation for combination with other functions
You can use this function in combination with the Muting, Floating Blanking and Warning Zone
functions at the same time with the SD Manager 3.
Refer to
for more information on the use in conjunction with other functions.
Settings for respective zone have limitations.
Refer to
2-19. Setting Zone Adjacency Conditions
for more information.
2-15-2. Factory Default Setting
Fixed Blanking is disabled.
Normal detecting beam
Fixed blanking beam
Allowable beam
Figure 4
Figure 3
Figure 1
Figure 2
Fixed blanking zone 1
Fixed blanking zone 2
Fixed blanking zone 1
Fixed blanking zone 2
Fixed blanking zone 1
(Allowable beam: 1 lower beam)
Fixed blanking zone 1
(Lower 1 allowable beam)
Fixed blanking zone 2
(Upper 1 allowable beam)
Fixed blanking zone 2
Upper
Upper
Upper
Upper
Lower
Lower
Lower
Lower
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...