121
F3SG-SR/PG
User’s Manual
Chapter
2
Reduced Resolution
System Operation and Functions
E
2-17-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
*It is not possible to configure the Reduced Resolution function together with the Muting function. To
enable settings of the Reduced Resolution function, disable the Muting function.
In addition, setting parameters of the following functions is saved according to the states where the
Muting function is enabled and disabled, respectively. After changing the Muting function from Enable
to Disable or from Disable to Enable with the SD Manager 3, also check the settings of these functions
again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary
Output
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Refer to
for more information on setting this function by the SD Manager 3.
Function name
Initial value
Configurable value or numerical range
Reduced Resolution
Disable
Enable*/Disable
Number of beams
1
1 to 3 beams in 1-beam increments
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...