155
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
3
Co
nne
ction
Setting with Intelligent Tap
E
For F3SG-SR-K, use a terminal block to connect to an intelligent tap as it is the open-ended type.
The figure below shows a connection example of F3SG-SR-K and the intelligent tap.
* To use the auxiliary output, the line must be wired separately from that of the Intelligent Tap.
If UL certification is required for the entire machine, you must select the terminal block that connects the F3SG-SR-K
and the intelligent tap as a UL-approved FW2 product.
Terminal #
Terminal name
Wire color
XS2H-D821-
H0-C
F3SG-SR-K receiver
1
Reset Input/External Device Monitoring
White
Yellow
2
+24V
Brown
Brown
3
Communication line (+)
Green
Gray
4
Communication line (-)
Yellow
Pink
5
Control Output 1
Gray
Black
6
Control Output 2
Pink
White
7
0V
Blue
Blue
8
Auxiliary Output
*
Red
Terminal #
Terminal name
Wire color
XS2H-D521-
G0-A
F3SG-SR-K emitter
1
+24V
Brown
Brown
2
TEST
White
Black
3
0V
Blue
Blue
4
Communication line (+)
Black
White
5
Communication line (-)
Gray
Yellow
Intelligent tap
XS2H-D
8
21-
H0-C
C
N
1
C
N
4
C
N
2
C
N
3
XS2H-D521-
G0-A
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...