183
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
3
IO
-L
ink
Setting with Intelligent Tap
E
Refer to
for more information on error codes and error descriptions.
81
(Primary
sensor
Receiver)
0
Error code
R
32 bytes
(8 bytes
x 4)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 4 records can be got.
* Please use the data for your inquiry.
0 if the sensor is not connected
82
(Secondary
sensor 1
Receiver)
0
Error code
R
32 bytes
(8 bytes
x 4)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 4 records can be got.
* Please use the data for your inquiry.
0 if the sensor is not connected
83
(Secondary
sensor 2
Receiver)
0
Error code
R
32 bytes
(8 bytes
x 4)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 4 records can be got.
* Please use the data for your inquiry.
0 if the sensor is not connected
84
(Primary
sensor
Emitter)
0
Error code
R
32 bytes
(8 bytes
x 4)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 4 records can be got.
* Please use the data for your inquiry.
0 if the sensor is not connected
85
(Secondary
sensor 1
Emitter)
0
Error code
R
32 bytes
(8 bytes
x 4)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 4 records can be got.
* Please use the data for your inquiry.
0 if the sensor is not connected
86
(Secondary
sensor 2
Emitter)
0
Error code
R
32 bytes
(8 bytes
x 4)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 4 records can be got.
* Please use the data for your inquiry.
0 if the sensor is not connected
160
0
Operation Time
Operation time
period
R
4 bytes
The Power-ON Time of Intelligent Tap (1 count every 1
hours)
Index
Sub-Index
Name
R/W
Length
Setting contents
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...