4-3-4-4. Pre-Reset
First, carry out
4-3-1. Preparing to Change Settings
Next, click the icon below on the Top page.
The setting screen below is displayed.
*1. When pre-reset is enabled, the pre-reset function takes priority, so the parameters of start interlock and restart interlock are
ignored.
*2. The minimum number of times is fixed to one.
For more information on pre-reset, refer to.
It is not possible to configure the Pre-Reset function together with the Muting function. To enable settings of the Pre-
Reset function, disable the Muting function. The setting parameters are kept individually in each case that the muting
function is set enabled or disabled.
After changing the Muting function from Enable to Disable or from Disable to Enable, check the settings of these
functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR.
To enable the written configuration, refer to
4-2-7-3. Writing Configuration into Intelligent Tap
When connecting the Intelligent Tap to a F3SG-SR/PG and trying to return the F3SG-SR/PG to [Detecting], follow step 4
of
4-1-3-2. Connection Procedure When Using USB Connector
to restart the F3SG-SR/PG and Intelligent Tap, or click
the [Monitor]
button.
F3SG-SRA
F3SG-PGA-A
F3SG-PGA-C
F3SG-SRB
F3SG-PGA-L
No.
Function name
Description
Initial value
Configurable
value or
numerical range
1
Pre-Reset function
Select Enable or Disable for the Pre-Reset function.
Disable
Enable/Disable
*1
2
Maximum number of times
F3SG-SR is blocked *2
Select desired maximum number the F3SG-SR can
be blocked in the Pre-Reset process. The minimum
number of times is 1.
If you want to set this item to infinite, select zero.
0 (infinite)
0 to 9 times (in
1-time
increments)
3
Maximum period of time from
input of PRE-RESET signal to
input of RESET signal
Select desired maximum time from inputting the
PRE-RESET signal to inputting the RESET signal.
8 s
1 to 60 s (in 1s
increments)
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...