System Operation and Functions
End conditions
If any of the following condition is satisfied, the MUTING state is released.
• When a workpiece passes the muting sensor A or B and the exit-only muting delay time (4 s: Can
be changed) passes.
• When a workpiece passes the F3SG-SR/PG's detection zone and the muting end wait time (1 s:
configurable) passes.
• The duration of the MUTING state exceeds the muting time limit (60 s: configurable).
The MUTING state is also released when the F3SG-SR/PG enters the LOCKOUT state.
Timing chart
Note. This timing chart shows the case in which the MUTING state was released under the condition of T4 (1 s).
Factory default setting
The MUTING state is also released when the F3SG-SR/PG enters the LOCKOUT state.
Variable
Variable name
Value
Description
T1min
Muting input time limit value
(minimum)
0.1 s
Minimum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is smaller
than this value, a muting sequence error occurs.
T1max
Muting input time limit value
(maximum)
4 s
Maximum time difference between muting inputs A and B.
If the time difference between muting inputs A and B is larger
than this value, a muting sequence error occurs.
T2
Muting time limit
60 s
The duration time of the Muting function. The MUTING state is
cancelled if it continues for longer than this time limit.
T3
Maximum allowable muting
signal interruption
0.1 s
Maximum duration of a signal interruption allowed in muting
inputs A and B.
T4
Muting end wait time
1 s
Time difference from when the F3SG-SR/PG is unblocked until
the MUTING state is cancelled.
T5
Exit-only muting delay time
4 s
Time difference from when the signal of Muting input A or B is
turned OFF until the MUTING state is cancelled.
O
N
OFF
M
u
ting inp
u
t A
(M
u
ting sensor A1)
M
u
ting inp
u
t B
(M
u
ting sensor B1)
Un
b
locked
Blocked
OSSD
O
N
OFF
MUTI
N
G state
Ena
b
led
Disa
b
led
O
N
OFF
Beam state
ABI indicator
O
N
OFF
T1min: M
u
ting inp
u
t time limit
v
al
u
e (minim
u
m)
T1max: M
u
ting inp
u
t time limit
v
al
u
e (maxim
u
m)
T2: M
u
ting time limit
T3: Maxim
u
m allo
w
a
b
le m
u
ting signal interr
u
ption
T4: M
u
ting end
w
ait time
T5: Exit-only m
u
ting delay time
T2 max.
8
0 ms max. *
T3 (0.1 s) max.
T4 (1 s)
T3 (0.1 s) max.
T1min to T1max
T5 max.
Green
b
linking
Orange
b
linking
* 102 ms max.
w
hen the
Intelligent Tap is connected
to the F3SG-SR/PG.
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...