97
F3SG-SR/PG
User’s Manual
Chapter
2
Mu
ti
ng
System Operation and Functions
E
If the duration between when the muting input A is turned ON from the OFF state and when the muting
input B is turned OFF from the ON state is within T1max [ s ], the safety function of the F3SG-SR/PG is
disabled.
Time t1 [ s ] for the F3SG-SR to enter MUTING state is within the range shown below:
t1 < T1max. . . . . . . . . . . Equation (5)
T1max [ s ] : Muting input time limit value (maximum)
The value of T1
max
can be changed by the SD Manager 3.
Timing Chart
G
u
ard fence
Limit s
w
itch1
(
N
O Contact)
Limit s
w
itch 2
(
N
C Contact)
D
u
ring m
u
ting
O
N
: To m
u
ting inp
u
t A
O
N
-> OFF: To m
u
ting inp
u
t B
Inp
u
t time difference
b
et
w
een m
u
ting inp
u
ts A and B
m
u
st
b
e T1max or less
(initial setting is 4 s)
F3SG-SR/PG
24
V
T1max: M
u
ting inp
u
t time limit
v
al
u
e (maxim
u
m)
T2: M
u
ting time limit
T3: Maxim
u
m allo
w
a
b
le m
u
ting signal interr
u
ption
T3 (0.1 s) max.
T1max.
T3 (0.1 s) max.
8
0 ms max. *
T2 max.
Orange
b
linking
Green
b
linking
Green O
N
Orange
b
linking
* 102 ms max.
w
hen the
Intelligent Tap is connected
to the F3SG-SR.
O
N
OFF
Un
b
locked
Blocked
OSSD
O
N
OFF
Ena
b
led
Disa
b
led
O
N
OFF
M
u
ting inp
u
t A
(Limit s
w
itch1)
M
u
ting inp
u
t B
(Limit s
w
itch2)
MUTI
N
G state
Beam state
ABI indicator
O
N
OFF
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...